13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Our Products › Adsorption Tower › Waste Incinerators

Adsorption Tower for Waste Incinerators

Activated carbon towers for solvent, VOC and odour removal. In waste incinerators the gas is incinerator flue gas, which decides the type, the media or material, and where the fan sits.

The process

Hazardous, medical and municipal waste incinerators hold the furnace under draft with an ID fan that sits after the quench, scrubber, bag filter and carbon injection. The gas at the fan is wet and acidic. Combustion air and secondary air blowers serve the primary and secondary chambers.

The gas

Flue gas after the quench and scrubber is wet, acidic and still carries fine dust. The fan is in stainless steel or lined construction, with a shaft seal and drains, sized at the saturated density.

Selection for this process

CarbonGranular activated carbon bed sized for the solvent load and the required outlet
FanSpark resistant, on the clean side of the bed

Types, construction and performance of the adsorption tower.

Industries

Fans in waste incinerators

Adsorption Tower in other processes

Information needed to select or quote

  1. Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
  2. Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
  3. Required outlet. The emission limit or clean gas concentration the unit must meet.
  4. Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote