Circulates or supplies air at elevated temperature to a dryer, oven or kiln. In tea dryers the gas at the fan is tea factory air, and that sets the blade form, the material and the drive.

The process

Fluid bed and endless chain pressure dryers fire the tea with hot air from a heater and exhaust the moist air with leaf fluff through a dust collector. Hot air fan on the supply, exhaust fan on the outlet.

The gas at the fan

Warm, humid air through withering troughs and dryers with light leaf dust. Large volume at low pressure; the fan is cleaned often, so access matters.

Selection for this duty

Blade formBackward inclined or backward curved; the residual dust does not justify a radial wheel
Material of constructionStainless steel wetted parts, with drains in the casing and a shaft seal
Drive and bearingsDirect coupled or belt driven; belt drive where the duty point may need tuning at site
Also specifiedCasing drain at the lowest point
Density at the fanAt about 60°C the gas density is close to 1.06 kg/m³, 88% of standard air. Pressure developed and power drawn fall in the same ratio, so the selection is made at this density and the motor is checked at cold start.

Circulates or supplies air at elevated temperature to a dryer, oven or kiln. Selected at the hot density with the shaft and bearing arrangement built for continuous hot running. Client-stated blade types for the Hot Air Fan in general: Backward curved and backward inclined.

Industries

Other fans in tea dryers

Hot Air Fan in other processes

Services on this fan

Information needed to select or quote

  1. Duty point. Volume flow and static pressure at the fan inlet, with the gas density and temperature or the conditions to derive it.
  2. Operating conditions. Site altitude, normal operating temperature and continuous or intermittent duty.
  3. Gas stream. Dust loading and particle size, corrosive species, moisture, upset temperature and any tendency of the material to deposit on the impeller.
  4. Mechanical. Rotation viewed from the drive end, discharge orientation and motor power.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote