13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Fans by Process › Clinker Grate Coolers

Fans and Air Pollution Control for Clinker Grate Coolers

The grate cooler takes clinker at over a thousand degrees and quenches it with air blown up through the grate by a row of compartment fans, each at its own pressure.

The process

The grate cooler takes clinker at over a thousand degrees and quenches it with air blown up through the grate by a row of compartment fans, each at its own pressure. The hot air not needed for combustion is exhausted by the cooler vent or cooler ID fan through an ESP or bag filter.

The gas

Surplus cooler air carrying clinker dust, hot and abrasive. Temperature swings with kiln operation, so the fan is selected across the band rather than at one point.

Fans in this process

DutyWhat it does hereType usually selected
Cooler Compartment FanBlows ambient air up through the grate of the clinker cooler.Backward curved and radial tipped
Cooler Vent FanExhausts the surplus hot air from the clinker cooler after the secondary and tertiary air have been taken off, drawing it through the cooler dust collector..Backward curved and radial tipped
Cooler ID FanDraws the clinker cooler exhaust through the cooler dust collector to the stack, holding the cooler hood under a slight negative pressure..Backward curved and radial tipped
Dust Collector FanThe fan behind a bag filter, cyclone or multiclone on a dust extraction system.Backward inclined and radial tipped
Bag Filter FanPulls the process gas through the filter bags and discharges the cleaned gas to the stack.Backward curved and radial tipped

Air pollution control

Industries

Related processes

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.