Primary Air Fan for Biomass Fired Boilers

Supplies the air that dries the pulverised fuel in the mill and carries it to the burners. In biomass fired boilers the gas at the fan is biomass boiler flue gas, and that sets the blade form, the material and the drive.

The process

Boilers firing wood chips, agricultural residue or briquettes see fuel that varies in moisture and ash from one delivery to the next. The fan set is sized for the worst fuel, with the ID fan handling fly ash that is fibrous and sometimes sticky, and the FD and SA fans giving enough margin to burn wet fuel.

The gas at the fan

Mixed biomass fuels give variable ash and moisture. The fan is sized for the worst fuel in the mix, with wear protection and deposit shedding as for bagasse.

Selection for this duty

Blade formRadial tipped with wear liners, or straight radial where the dust is coarse
Material of constructionMild steel with replaceable wear liners on the blades and the scroll at the cut-off, with a casing drain for the moisture
Drive and bearingsDirect coupled or belt driven with a shaft cooling disc and bearings outside the casing
Also specifiedHard facing or liners on the blade pressure face; casing drain at the lowest point
Density at the fanAt about 170°C the gas density is close to 0.80 kg/m³, 66% of standard air. Pressure developed and power drawn fall in the same ratio, so the selection is made at this density and the motor is checked at cold start.

Supplies the air that dries the pulverised fuel in the mill and carries it to the burners. Runs at higher pressure than the FD fan because it must overcome the mill and the fuel piping. Client-stated blade types for the PA Fan in general: Backward curved and radial tipped.

Industries

Other fans in biomass fired boilers

PA Fan in other processes

Services on this fan

Information needed to select or quote

  1. Duty point. Volume flow and static pressure at the fan inlet, with the gas density and temperature or the conditions to derive it.
  2. Operating conditions. Site altitude, normal operating temperature and continuous or intermittent duty.
  3. Gas stream. Dust loading and particle size, corrosive species, moisture, upset temperature and any tendency of the material to deposit on the impeller.
  4. Mechanical. Rotation viewed from the drive end, discharge orientation and motor power.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote