What the fans do here
Food plants need stainless steel fans for dryer and oven exhaust, dust extraction on milling and mixing with bag filters, and ventilation and AHUs that hold the processing area at the required temperature and air quality.
Applications in this industry
| Application | What it does | Type usually selected |
|---|---|---|
| Hot Air Fan | Circulates or supplies air at elevated temperature to a dryer, oven or kiln. Selected at the hot density with the shaft and bearing arrangement built for continuous hot running. | Backward curved and backward inclined |
| Dust Collector Fan | The fan behind a bag filter, cyclone or multiclone on a dust extraction system. Placed on the clean side where possible so the blade can be chosen for efficiency. | Backward inclined and radial tipped |
| Ventilation Fan | Moves air through a plant or building for fresh air supply, heat removal and fume dilution where the system is ducted. Low pressure, long hours, so efficiency and noise set the selection. | Backward inclined and forward curved |
| HVAC | Supply, return and exhaust fans for heating, ventilation and air conditioning of plant and office space. Low pressure, so efficiency and noise govern. | Axial, backward inclined and forward curved |
| AHU | A packaged unit with fan, filters, cooling or heating coil and mixing box that conditions and delivers supply air. Pre, fine and HEPA filters as the air quality requires. | Backward curved and forward curved |
Processes in this industry
Equipment supplied

Centrifugal Fans
0.3 to 120 m³/s, 25 to 3120 mmWC single stage. Six blade configurations, three drive arrangements.

Bag Filter
Fabric filters in polyester, polypropylene, Ryton and Nomex. Efficiency to 99.9% down to 5 micron.

Axial Fans
0.3 to 70 m³/s, 3 to 75 mmWC. Direct drive, belt drive and bifurcated. Fixed or variable pitch impellers.

Ventilation System
Supply and exhaust ventilation, evaporative cooling, roof extractors, jet fans and air distribution.
Information needed to select or quote
- Duty point. Volume flow and static pressure at the fan inlet, with the gas density and temperature or the conditions to derive it.
- Operating conditions. Site altitude, normal operating temperature and continuous or intermittent duty.
- Gas stream. Dust loading and particle size, corrosive species, moisture, upset temperature and any tendency of the material to deposit on the impeller.
- Mechanical. Rotation viewed from the drive end, discharge orientation and motor power.