13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Fans by Process › Biomass Fired Boilers

Fans and Air Pollution Control for Biomass Fired Boilers

Boilers firing wood chips, agricultural residue or briquettes see fuel that varies in moisture and ash from one delivery to the next.

The process

Boilers firing wood chips, agricultural residue or briquettes see fuel that varies in moisture and ash from one delivery to the next. The fan set is sized for the worst fuel, with the ID fan handling fly ash that is fibrous and sometimes sticky, and the FD and SA fans giving enough margin to burn wet fuel.

The gas

Mixed biomass fuels give variable ash and moisture. The fan is sized for the worst fuel in the mix, with wear protection and deposit shedding as for bagasse.

Fans in this process

DutyWhat it does hereType usually selected
ID FanSits at the outlet of a boiler, kiln or furnace and draws the flue gas through the plant to the stack.Backward curved, backward inclined and radial tipped
FD FanSupplies combustion air to a boiler or furnace, pushing ambient air through the air heater and into the windbox against the furnace draft.Backward curved and backward inclined
SA FanSupplies the secondary combustion air that completes burning above the grate or around the burner.Backward curved and backward inclined
PA FanSupplies the air that dries the pulverised fuel in the mill and carries it to the burners.Backward curved and radial tipped
Combustion Air BlowerFeeds a burner with air at the pressure the burner register needs.Backward curved and radial tipped
Seal Air BlowerSupplies clean air at a pressure above the mill or fan casing pressure to the shaft seals and bearing housings, so pulverised coal cannot enter..Backward curved and radial
Dust Collector FanThe fan behind a bag filter, cyclone or multiclone on a dust extraction system.Backward inclined and radial tipped
Bag Filter FanPulls the process gas through the filter bags and discharges the cleaned gas to the stack.Backward curved and radial tipped
Fan SilencerAn absorptive silencer at the fan inlet, outlet or in the duct, cutting fan noise with minimum pressure loss..Silencer
Vent SilencerCuts the noise from steam or gas expanding from high pressure to atmosphere at safety valve outlets, start-up vents and blow-down lines..Silencer
Ventilation FanMoves air through a plant or building for fresh air supply, heat removal and fume dilution where the system is ducted.Backward inclined and forward curved
Dilution Air BlowerInjects ambient air into a hot flue gas stream to bring it down to a temperature the downstream bag filter or fan can accept..Backward curved

Industries

Related processes

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote