An absorptive silencer at the fan inlet, outlet or in the duct, cutting fan noise with minimum pressure loss.

Selection

ProductSilencer
IndustriesBoiler, Power, Furnaces, Oil & Gas, Nuclear

In each industry

Boiler

A boiler house runs on draft. The FD fan pushes combustion air through the air heater into the windbox, the PA fan carries pulverised fuel from the mill to the burners, and the ID fan pulls the flue gas through the economiser, air heater and dust collector to the stack. The ID fan sees the worst duty: hot gas, fly ash and a pressure that rises as the filter loads. Bag filters or multiclones sit ahead of it, and silencers on the FD inlet keep the boiler house within noise limits.

Power

Thermal power stations use the full boiler fan set at the largest sizes: ID fans on the flue gas after the ESP, FD fans for secondary air, PA fans for mill air, and seal air blowers to keep pulverised coal out of the mill bearings. Coal handling plants add dust extraction fans on the crushers and transfer points, with bag filters and cyclones on the collected air.

Furnaces

Heat treatment, forging and melting furnaces need combustion air blowers sized for the burner pressure, hot air fans for recirculation in the furnace chamber, and exhaust fans on the flue that can live with gas at several hundred degrees. Dilution air blowers bring the flue gas down to a temperature the filter can accept.

Oil & Gas

Refineries and gas plants use fans on fired heaters and boilers (FD and ID), on flare and vent systems (vent silencers on relief and blow-down lines), and on process vessels where a knock-out drum separates liquid from vapour ahead of a compressor. Explosion-proof motors and spark-resistant construction are standard.

Nuclear

Nuclear facilities use ventilation systems that hold the building under controlled negative pressure, with HEPA-filtered exhaust and AHUs on the supply side. Fans are specified for reliability and for filtration efficiency rather than for dust or heat.

By process

The same duty, selected for the gas of each process.

See the Silencer page for construction, types and selection data.

Information needed to select or quote

  1. Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
  2. Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
  3. Required outlet. The emission limit or clean gas concentration the unit must meet.
  4. Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.