Hot Air Fan for Powder Coating Lines

Circulates or supplies air at elevated temperature to a dryer, oven or kiln. In powder coating lines the gas at the fan is ambient air with nuisance dust, and that sets the blade form, the material and the drive.

The process

Powder booths recover overspray through cartridge filters with the extraction fan on the clean side, and the curing oven uses recirculation fans. Pretreatment tanks add fume extraction.

The gas at the fan

Ambient air carrying light dust from the surroundings, enough to settle on blades over months but not to erode them. Inlet screens and a wheel that sheds deposit are the usual precautions.

Selection for this duty

Blade formBackward inclined or backward curved; the residual dust does not justify a radial wheel
Material of constructionMild steel
Drive and bearingsDirect coupled or belt driven; belt drive where the duty point may need tuning at site
Density at the fanAt about 35°C the gas density is close to 1.15 kg/m³, 95% of standard air. Pressure developed and power drawn fall in the same ratio, so the selection is made at this density and the motor is checked at cold start.

Circulates or supplies air at elevated temperature to a dryer, oven or kiln. Selected at the hot density with the shaft and bearing arrangement built for continuous hot running. Client-stated blade types for the Hot Air Fan in general: Backward curved and backward inclined.

Industries

Other fans in powder coating lines

Hot Air Fan in other processes

Services on this fan

Information needed to select or quote

  1. Duty point. Volume flow and static pressure at the fan inlet, with the gas density and temperature or the conditions to derive it.
  2. Operating conditions. Site altitude, normal operating temperature and continuous or intermittent duty.
  3. Gas stream. Dust loading and particle size, corrosive species, moisture, upset temperature and any tendency of the material to deposit on the impeller.
  4. Mechanical. Rotation viewed from the drive end, discharge orientation and motor power.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote