The process
An atmospheric fluidised bed boiler keeps a bed of sand and ash in suspension with a high pressure FD fan under the distributor plate, and the flue gas carries bed fines and fly ash to the ESP or bag filter. The FD fan is a pressure duty, the ID fan a volume duty with abrasive dust, and the PA fan feeds the fuel feeders where they are pneumatic.
The gas
Fluidised bed combustion carries bed material fines and fly ash in the flue gas. The dust is abrasive and the loading ahead of the collector is high, so the ID fan is placed after the dust collector wherever the layout allows.
Fans in this process
| Duty | What it does here | Type usually selected |
|---|---|---|
| ID Fan | Sits at the outlet of a boiler, kiln or furnace and draws the flue gas through the plant to the stack. | Backward curved, backward inclined and radial tipped |
| FD Fan | Supplies combustion air to a boiler or furnace, pushing ambient air through the air heater and into the windbox against the furnace draft. | Backward curved and backward inclined |
| SA Fan | Supplies the secondary combustion air that completes burning above the grate or around the burner. | Backward curved and backward inclined |
| PA Fan | Supplies the air that dries the pulverised fuel in the mill and carries it to the burners. | Backward curved and radial tipped |
| Combustion Air Blower | Feeds a burner with air at the pressure the burner register needs. | Backward curved and radial tipped |
| Seal Air Blower | Supplies clean air at a pressure above the mill or fan casing pressure to the shaft seals and bearing housings, so pulverised coal cannot enter.. | Backward curved and radial |
| Dust Collector Fan | The fan behind a bag filter, cyclone or multiclone on a dust extraction system. | Backward inclined and radial tipped |
| Bag Filter Fan | Pulls the process gas through the filter bags and discharges the cleaned gas to the stack. | Backward curved and radial tipped |
| Fan Silencer | An absorptive silencer at the fan inlet, outlet or in the duct, cutting fan noise with minimum pressure loss.. | Silencer |
| Vent Silencer | Cuts the noise from steam or gas expanding from high pressure to atmosphere at safety valve outlets, start-up vents and blow-down lines.. | Silencer |
| Ventilation Fan | Moves air through a plant or building for fresh air supply, heat removal and fume dilution where the system is ducted. | Backward inclined and forward curved |