13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Fans by Process › AFBC Boilers

Fans and Air Pollution Control for AFBC Boilers

An atmospheric fluidised bed boiler keeps a bed of sand and ash in suspension with a high pressure FD fan under the distributor plate, and the flue gas carries bed fines and fly ash to the ESP or bag filter.

The process

An atmospheric fluidised bed boiler keeps a bed of sand and ash in suspension with a high pressure FD fan under the distributor plate, and the flue gas carries bed fines and fly ash to the ESP or bag filter. The FD fan is a pressure duty, the ID fan a volume duty with abrasive dust, and the PA fan feeds the fuel feeders where they are pneumatic.

The gas

Fluidised bed combustion carries bed material fines and fly ash in the flue gas. The dust is abrasive and the loading ahead of the collector is high, so the ID fan is placed after the dust collector wherever the layout allows.

Fans in this process

DutyWhat it does hereType usually selected
ID FanSits at the outlet of a boiler, kiln or furnace and draws the flue gas through the plant to the stack.Backward curved, backward inclined and radial tipped
FD FanSupplies combustion air to a boiler or furnace, pushing ambient air through the air heater and into the windbox against the furnace draft.Backward curved and backward inclined
SA FanSupplies the secondary combustion air that completes burning above the grate or around the burner.Backward curved and backward inclined
PA FanSupplies the air that dries the pulverised fuel in the mill and carries it to the burners.Backward curved and radial tipped
Combustion Air BlowerFeeds a burner with air at the pressure the burner register needs.Backward curved and radial tipped
Seal Air BlowerSupplies clean air at a pressure above the mill or fan casing pressure to the shaft seals and bearing housings, so pulverised coal cannot enter..Backward curved and radial
Dust Collector FanThe fan behind a bag filter, cyclone or multiclone on a dust extraction system.Backward inclined and radial tipped
Bag Filter FanPulls the process gas through the filter bags and discharges the cleaned gas to the stack.Backward curved and radial tipped
Fan SilencerAn absorptive silencer at the fan inlet, outlet or in the duct, cutting fan noise with minimum pressure loss..Silencer
Vent SilencerCuts the noise from steam or gas expanding from high pressure to atmosphere at safety valve outlets, start-up vents and blow-down lines..Silencer
Ventilation FanMoves air through a plant or building for fresh air supply, heat removal and fume dilution where the system is ducted.Backward inclined and forward curved

Industries

Related processes

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote