Solid fuel thermic fluid heaters supply process heat in textile, chemical and food plants.

The process

Solid fuel thermic fluid heaters supply process heat in textile, chemical and food plants. The combustion side mirrors a small boiler: an FD fan under the grate or bed and an ID fan after the dust collector, both sized for the fuel in use.

The gas

Fluidised bed combustion carries bed material fines and fly ash in the flue gas. The dust is abrasive and the loading ahead of the collector is high, so the ID fan is placed after the dust collector wherever the layout allows.

Fans in this process

DutyWhat it does hereType usually selected
ID FanSits at the outlet of a boiler, kiln or furnace and draws the flue gas through the plant to the stack.Backward curved, backward inclined and radial tipped
FD FanSupplies combustion air to a boiler or furnace, pushing ambient air through the air heater and into the windbox against the furnace draft.Backward curved and backward inclined
Combustion Air BlowerFeeds a burner with air at the pressure the burner register needs.Backward curved and radial tipped
Dust Collector FanThe fan behind a bag filter, cyclone or multiclone on a dust extraction system.Backward inclined and radial tipped
Fan SilencerAn absorptive silencer at the fan inlet, outlet or in the duct, cutting fan noise with minimum pressure loss..Silencer

Industries

Related processes

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.