The process
Basic oxygen converters produce a short, intense burst of hot, carbon monoxide rich gas at each blow. The gas is cooled and cleaned in a wet scrubber or dry ESP and drawn by an ID fan that is sized for the peak of the blow and built for the gas to be flared or recovered. Secondary dedusting takes the fume at charging and tapping into a bag filter.
The gas
Fume from arc, induction or reverberatory furnaces, hot and carrying fine metallic oxide dust. Temperature is handled by dilution air or a cooler ahead of the filter, and the fan sits on the clean side where possible.
Selection for this process
| Type | Venturi for fine dust |
| Material | Stainless steel |
| Outlet | Mist eliminator ahead of the fan; fan in the same material as the scrubber |
Types, construction and performance of the wet scrubber.
Industries
Fans in bof steel converters
Wet Scrubber in other processes
Information needed to select or quote
- Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
- Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
- Required outlet. The emission limit or clean gas concentration the unit must meet.
- Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.