13, Galaxy Road, Ponniamman Nagar, Ayanambakkam, Chennai 600 095 +91 91766 67102  |  +91 91766 67103  |  marketing@adroitfantech.com
Home › Our Products › Wet Scrubber › Lead Smelting and Battery Recycling

Wet Scrubber for Lead Smelting and Battery Recycling

Static, spray tower, packed bed, venturi and cyclonic spray types. Efficiency to 99.9% down to 5 micron. In lead smelting and battery recycling the gas is melt shop fume, which decides the type, the media or material, and where the fan sits.

The process

Rotary and reverberatory furnaces for secondary lead emit fume with lead oxide and sulphur dioxide. The furnace off-gas is cooled, filtered in a bag filter and scrubbed, and the building is held under negative pressure for hygiene.

The gas

Fume from arc, induction or reverberatory furnaces, hot and carrying fine metallic oxide dust. Temperature is handled by dilution air or a cooler ahead of the filter, and the fan sits on the clean side where possible.

Selection for this process

TypeVenturi for fine dust
MaterialStainless steel
OutletMist eliminator ahead of the fan; fan in the same material as the scrubber

Types, construction and performance of the wet scrubber.

Industries

Fans in lead smelting and battery recycling

Wet Scrubber in other processes

Information needed to select or quote

  1. Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
  2. Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
  3. Required outlet. The emission limit or clean gas concentration the unit must meet.
  4. Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.

Send us your duty point

Flow, pressure, gas condition and temperature are enough to start a selection.

Get a quote