The process
Reactors, storage tanks and process vents release acid, alkali or organic vapour that is scrubbed before discharge. The vent fan is in PP-FRP, FRP or stainless steel to suit the vapour, with the motor outside the gas path and a mist eliminator on the scrubber outlet.
The gas
Fume from pickling, acid handling or reactor vents, corrosive and often wet. PP-FRP, FRP or rubber lined construction, with the motor outside the gas path.
Selection for this process
| Type | Packed bed for gas absorption |
| Material | PP-FRP or rubber lined |
| Outlet | Mist eliminator ahead of the fan; fan in the same material as the scrubber |
Types, construction and performance of the wet scrubber.
Industries
Fans in chemical reactor and tank vents
Wet Scrubber in other processes
Information needed to select or quote
- Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
- Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
- Required outlet. The emission limit or clean gas concentration the unit must meet.
- Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.
