The process
Grit blasting halls recover abrasive and dust through cyclones and bag filters, and painting halls exhaust solvent-laden air with overspray. Large volumes at low pressure, spark resistant where solvent is present.
The gas
Booth exhaust carries paint overspray that cures on anything it lands on, with solvent vapour. Spark resistant, a blade form that is easy to clean, and the fan after the booth filters or scrubber.
Selection for this process
| Type | Spray tower or cyclonic spray |
| Material | Stainless steel |
| Outlet | Mist eliminator ahead of the fan; fan in the same material as the scrubber |
Types, construction and performance of the wet scrubber.
Industries
Fans in blasting and painting halls
Wet Scrubber in other processes
Information needed to select or quote
- Gas volume and temperature. Actual flow at the inlet, normal and upset temperature, moisture.
- Dust or pollutant. Inlet loading, particle size distribution, whether it is abrasive, sticky, hygroscopic or combustible; for gases, the species and concentration.
- Required outlet. The emission limit or clean gas concentration the unit must meet.
- Site. Available space and height, material of construction preferences, and how the collected material is to be discharged.